| Base material | Glass cloth (GC) |
| Resin | Epoxy (EP) |
| Certificates |
DIN 5510/2 DIN 5510/2 Appendix C UL 94 (certificated) DIN EN 45545-2 |
| Properties | fire protection charge |
| Formate | IØ 8-590 x approx. 1000 mm |
| Application | kriechstromfest; WK 155; UL 94 V-0 |
| Flexural strength perpendicular to layer direction ISO 178 MPa min | 300 |
| Compressive strength axial ISO 604 MPa min | 175 |
| Adhesion between layers IEC 61212-2 MPa min | 200 |
| Dielectric strength perpendicular IEC 60243-1 kV/mm min | 7,7 |
| Breakdown voltage parallel IEC 60243-1 kV min | 40 |
| Insulation resistance IEC 60167 MΩ min | 1000 |
| Themal enduracne IEC 60216 T.I. min | 130 |
| Water absorption ISO 62 mg/cm² max | 1,5 |
| Density ISO 1183 g/cm³ | 1,7 - 1,9 |
| Flammability UL 94 (6) Kategorie halogenfrei | V-0 |
| Fire testing railways EN 45545-2 | R23/R24 |
| Fire testing railways DIN 5510-2 | S4/SR2/ST2 |
| Glowing wire ignition temperature EN 60695-2-13 GWIT | >960/3,0 |