| Base material | Glass cloth (GC) |
| Resin | Epoxy (EP) |
| Certificates |
DIN 5510/2 DIN 5510/2 Appendix C UL 94 (certificated) DIN EN 45545-2 |
| Properties |
resistance against tracking CTI 600 fire protection charge |
| Formate |
ca. 2780 x 1200 mm ca. 1390 x 1200 mm ca. 2150 x 1020 mm ca. 1075 x 1020 mm ca. 1050 x 1020 mm Special sizes upon request |
| Application | hoch kriechstromfest CTI 600M; WK 155; UL 94 V-0 |
| Dielectric strength perpendicular IEC 60243-1 kV/mm min | 10,2 |
| Breakdown voltage parallel IEC 60243-1 kV min | 45 |
| Insulation resistance IEC 60167 MΩ min | 50.000 |
| Themal enduracne IEC 60216 T.I. min | 155 |
| Density ISO 1183 g/cm³ | 1,8 - 2,0 |
| Fire testing railways DIN 5510-2 | S4/SR2/ST2 |
| CTI IEC 60112 min | 600 |
| Glowing wire ignition temperature EN 60695-2-13 GWIT | 960/3,0 |
| Flexural strength ISO 178 MPa min | 340 |
| Elastic modulus from bending test ISO 178 MPa min | 22.000 |
| Compressive strength perpendicular ISO 604 MPa min | 350 |
| Impact strength ISO 179/3C kJ/m² min | 50 |
| Tensile strength ISO 527-4 MPa min | 300 |
| Flammability UL 94 Kat. | V-0 |
| Water absorption Tabelle 10mm | 34 |
| Glowing wire flammability EN 60695-2-12 GWFI | 960/3,0 |