Base material | Glass cloth (GC) |
Resin | Epoxy (EP) |
Certificates |
DIN 5510/2 DIN 5510/2 Appendix C UL 94 (certificated) DIN EN 45545-2 |
Properties | fire protection charge |
Formate | IØ 8-590 x approx. 1000 mm |
Application | hoch kriechstromfest CTI 600M; WK 155; UL 94 V-0 |
Flexural strength perpendicular to layer direction ISO 178 MPa min | 300 |
Compressive strength axial ISO 604 MPa min | 175 |
Adhesion between layers IEC 61212-2 MPa min | 200 |
Dielectric strength perpendicular IEC 60243-1 kV/mm min | 7,7 |
Breakdown voltage parallel IEC 60243-1 kV min | 40 |
Insulation resistance IEC 60167 MΩ min | 1000 |
Themal enduracne IEC 60216 T.I. min | 130 |
Water absorption ISO 62 mg/cm² max | 1,5 |
Density ISO 1183 g/cm³ | 1,7 - 1,9 |
Flammability UL 94 (6) Kategorie halogenfrei | V-0 |
Fire testing railways EN 45545-2 | R22/R23 |
Fire testing railways DIN 5510-2 | S4/SR2/ST2 |
CTI IEC 60112 min | 600 M |
Glowing wire ignition temperature EN 60695-2-13 GWIT | 930/3,0 |