Base material Glass cloth (GC)
Resin Epoxy (EP)
Certificates DIN 5510/2
DIN 5510/2 Appendix C
UL 94 (certificated)
DIN EN 45545-2
Properties fire protection charge
Formate IØ 8-590 x approx. 1000 mm
Application hoch kriechstromfest CTI 600M; WK 155; UL 94 V-0
Flexural strength perpendicular to layer direction
ISO 178 MPa min
300
Compressive strength axial
ISO 604 MPa min
175
Adhesion between layers
IEC 61212-2 MPa min
200
Dielectric strength perpendicular
IEC 60243-1 kV/mm min
7,7
Breakdown voltage parallel
IEC 60243-1 kV min
40
Insulation resistance
IEC 60167 MΩ min
1000
Themal enduracne
IEC 60216 T.I. min
130
Water absorption
ISO 62 mg/cm² max
1,5
Density
ISO 1183 g/cm³
1,7 - 1,9
Flammability
UL 94 (6) Kategorie halogenfrei
V-0
Fire testing railways
EN 45545-2
R22/R23
Fire testing railways
DIN 5510-2
S4/SR2/ST2
CTI
IEC 60112 min
600 M
Glowing wire ignition temperature
EN 60695-2-13 GWIT
930/3,0
Add product to review listing